2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
Op voorraad
Waarom je van winkelen bij OnBuy zult houden:
- Verdien Cashback bij elke aankoop – besteed het direct aan je volgende bestelling
- Gratis bezorging – op miljoenen artikelen op de site
- Klanten waarderen ons – 132,000 beoordelingen met een “Uitstekende” score
Prijzen zijn inclusief btw.
Rentevrije betaalopties beschikbaar
Bekijk de volledige productbeschrijving & details
Bezorging: Standaard (€ 4,20) | di 1ste - ma 7de sep.
Retouren: 30 dagen
180 dagen betalingsbescherming
Misschien vind je dit ook leuk
Samenvatting
- Single-control UP pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B(blue)-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common line.D(green) and E(yellow)are connected with C (black).
- Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common line.A and B-disconnected
- Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
- Joint control UP and DOWN pool installation instructions :A-Upper water level control point in UP pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
- C-Should be placed in bottom of UP and DOWN pools as the common line.D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay Beschrijving
Single-control pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B()-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common .D(green) and E(yellow)are connected with C (black).
Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common .A and B-disconnected
Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
Joint control and DOWN pool installation instructions :A-Upper water level control point in pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
C-Should be placed in bottom of and DOWN pools as the common .D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
Type:DF-96D Updated version
Working
Details
| OPC | PTRH9FQ |
|---|---|
| Codes | 4712044178640 (EAN) |
| Product- en veiligheidsinformatie |
Productgegevens
| Height | 12cm |
|---|---|
| Width | 9cm |
| Length | 11cm |
| Weight | 0.443kg |
| Colour | creamy-white |
| Material | plastic |
Vergelijk verkopers voor 2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
- Nieuw van € 30,25
| Verkoper | Beoordelingen | Garantie | Retourneren | Prijs | Bezorging | Totaal | Aantal |
|---|---|---|---|---|---|---|---|
|
Verzonden vanuit:
|
(121 beoordelingen) | - |
30 dagen
Gratis retourneren Nee
|
€ 26,05
|
+€ 4,20 Delivery
Geschatte bezorging:
1ste-7de sep.
|
€ 30,25
|
Verdien terwijl je shopt met directe Cashback op alles.
Geen addertjes, geen kosten
- Uitbetaald op je OnBuy-account
- Besteed het bij je volgende aankoop
- Bewaar het of neem het op
Word een Cashback VIP
Slechts 1 aankoop ontgrendelt grotere deals en kortingen