pH and Chlorine Controller Sensor Probe for Accurate and Reliable Water Testing and Pool Maintenance
In stock
Smart shoppers OnBuy it!
- Earn Cashback on every purchase – spend it instantly on your next order
- Free delivery – on millions of items across the site
- Customers love us – 139,000 Trustpilot reviews and an 'Excellent' rating
All prices include VAT.
Interest-free payment options available
See full product description & details
Delivery: Standard (Free) | Thu 3rd - Tue 8th Dec
Sold by: ALICJAANNAP
Returns: 30 days
180-day payment protection
pH and Chlorine Controller Sensor Probe for Accurate and Reliable Water Testing and Pool Maintenance Description
Working Environment
1. Ambient temperature: 5 to 40C.
2. Ambient relative humidity: 85%.
Use, Maintenance and Precautions
1. Before testing, remove the protective cover from the electrode. The solution inside the cover is 3 M KCl. If crystals appear, this is normal and does not affect electrode performance.
2. Check that the sensitive glass bulb is completely filled with liquid. If bubbles are present, gently shake the electrode like a thermometer to move the bubbles out of the sensitive bulb; otherwise, test accuracy may be affected.
Electrode and pH Meter Calibration and Testing
1. Connect the pH electrode to the input terminal of the pH instrument and ensure that the connection is secure and correct.
2. Calibrate the electrode according to the instrument's operating instructions. The calibration result should then be measured.
Storage and Maintenance of the Liquid-Filled Combination pH Electrode
1. The electrode uses a liquid-filled structure. Clean it with distilled water and place it in the protective bottle. Before the next test, activate it by replenishing the solution.
2. If the electrode will not be used for an extended period, rinse it and remove any remaining distilled water.
3. Do not allow the sensitive glass bulb at the front of the electrode to contact hard objects. Damage or scratches may cause the electrode to become unusable.
4. After prolonged use, the electrode's slope and response speed may decrease. To restore performance, immerse the measuring end in 4% hydrofluoric acid for 3 to 5 seconds or in a diluted hydrochloric acid solution for 1 to 2 minutes. Then rinse it with distilled water and soak it in 4 M potassium chloride solution.
5. If the tested container contains substances that can easily contaminate the sensitive bulb or block the liquid junction, the electrode may become passivated. This can significantly slow the response, reduce the slope, or cause unstable readings. Select a suitable cleaning solution according to the type of contaminant to restore the electrode.
Specifications
Heating voltage: 5 0.2 V AC/DC
Operating current: 5 to 10 mA
Detectable concentration range: pH 0 to 14
Detection temperature range: 0 to 80C
Response time: 5 seconds
Settling time: 60 seconds
Component power: 0.5 W
Operating temperature: -10 to 50C; rated temperature: 20C
Humidity: 95% relative humidity; rated humidity: 65% relative humidity
Module dimensions: 42 mm 32 mm 20 mm
Output: analogue voltage signal output
Mounting: four M3 mounting holes
Details
| OPC | PYV88KG |
|---|---|
| Codes | 8794844756446 (EAN) |
| Product and Safety Information |
Customers also buy
Compare Sellers for pH and Chlorine Controller Sensor Probe for Accurate and Reliable Water Testing and Pool Maintenance
- New from €43.99
| Seller | Ratings | Warranty | Returns | Price | Delivery | Total | Quantity |
|---|---|---|---|---|---|---|---|
|
Dispatched from:
|
(16 reviews) | - |
30 Days
Free Returns No
|
€43.99
|
+Free Delivery
Est. Delivery:
3rd-8th Dec
|
€43.99
|
Earn as you shop with instant Cashback on everything.
No catch, no cost
- Paid into your OnBuy account
- Spend it on your next purchase
- Save it or withdraw it
Become a Cashback VIP
Just 1 purchase unlocks bigger deals & rates