XY-WFTX Remote WIFI Thermostat Temperature Control Module NTC 10K 0.5M Relay Temperature Controller Module
Skladem
Proč si zamilujete nakupování na OnBuy:
- Získejte Cashback při každém nákupu – využijte jej okamžitě při další objednávce
- Doprava zdarma – u milionů položek na celém webu
- Zákazníci nás mají rádi – 135,000 recenzí s hodnocením “Vynikající”
Ceny zboží prodávaného na OnBuy jsou zobrazeny včetně DPH.
Možnosti platby bez úroků k dispozici
Zobrazit kompletní popis a podrobnosti o produktu
Doručení: Standardní (121,00 Kč) | úte 20 - pon 26 říj
Prodává: GSbuy
Vrácení zboží: 30 dní
180denní ochrana platby
Shrnutí
- 1. Function description of automatic mode: 1) First select heating mode/cooling mode. 2) Set the temperature and hysteresis difference, if you need to delay start, set the time of delay start. 3) If you need to set high and low temperature alarms, set the high and low temperature alarm thresholds yourself
- 2. Description of heating mode: When the detected temperature (current temperature) less than equal set temperature - hysteresis temperature, the relay is turned on, and the heating equipment starts to work. When the detected temperature (current temperature) greater than equal the set temperature, the relay is disconnected and the heating device stops working
- 3. Description of cooling mode: When the detected temperature (current temperature) greater than equal set temperature + hysteresis temperature, the relay is turned on, and the refrigeration equipment starts to work. When the detected temperature (current temperature) less than equal the set temperature, the relay is disconnected and the refrigeration equipment stops working
- 4. Description of delayed start function: After a heating/cooling process is over, how long to delay (unit: seconds) to allow the next heating/cooling. Temperature correction function: If the system works for a long time, there may be deviations, which can be corrected by this function, the current temperature = measured temperature + calibration value
- 5. Emergency braking function (emergency stop function): After the emergency stop is turned on, the relay will be disconnected no matter what state it is in; after the emergency stop is turned off, the relay returns to the normal state. In the automatic mode, when the parameters are set, the product can be disconnected from the network and run offline, and the parameters will not be lost when the power is turned off.
XY-WFTX Remote WIFI Thermostat Temperature Control Module NTC 10K 0.5M Relay Temperature Controller Module Popis
1. Function description of automatic mode: 1) First select heating mode/cooling mode. 2) Set the temperature and hysteresis difference, if you need to delay start, set the of delay start. 3) If you need to set high and low temperature alarms, set the high and low temperature alarm thresholds yourself
2. Description of heating mode: When the detected temperature (current temperature) less than equal set temperature - hysteresis temperature, the relay is turned , and the heating equipment starts to work. When the detected temperature (current temperature) greater than equal the set temperature, the relay is disconnected and the heating device stops working
3. Description of cooling mode: When the detected temperature (current temperature) greater than equal set temperature + hysteresis temperature, the relay is turned , and the refrigeration equipment starts to work. When the detected temperature (current temperature) less than equal the set temperature, the relay is disconnected and the refrigeration equipment stops working
4. Description of delayed start function: After a heating/cooling process is over, how long to delay (unit: seconds) to allow the next heating/cooling. Temperature correction function: If the system works for a long , there may be deviations, which can be corrected by this function, the current temperature = measured temperature + calibration value
5. Emergency braking function (emergency stop function): After the emergency stop is turned , the relay will be disconnected no matter what state it is in; after the emergency stop is turned off, the relay returns to the normal state. In the automatic mode, when the parameters are set, the product can be disconnected from the network and run offline, and the parameters will not be lost when the power is turned off.
High and low temperature alarm function
Podrobnosti
| OPC | PS5XHVM |
|---|---|
| Kódy | 6032785980011 (EAN) |
| Informace o produktu a bezpečnosti |
Produktová data
| Height | 2cm |
|---|---|
| Width | 5cm |
| Length | 7cm |
| Weight | 0.034kg |
| Colour | Black |
| Material | plastic |
Porovnejte prodejce pro XY-WFTX Remote WIFI Thermostat Temperature Control Module NTC 10K 0.5M Relay Temperature Controller Module
- Nové od 556,08 Kč
| Prodejce | Hodnocení | Záruka | Vrácení zboží | Cena | Doručení | Celkem | Množství |
|---|---|---|---|---|---|---|---|
|
Odesláno z:
|
(192 recenzí) | - |
30 dní
Vrácení zboží zdarma Ne
|
435,08 Kč
|
+121,00 Kč Delivery
Odhadované doručení:
20-26 říj
|
556,08 Kč
|
Získávejte odměny při nákupu s okamžitým Cashback na vše.
Žádný háček, žádné náklady
- Připsáno na váš účet OnBuy
- Využijte je při dalším nákupu
- Ušetřete nebo si je vyberte
Staňte se Cashback VIP
Už po 1 nákupu získáte lepší nabídky a ceny