XY-WFTX Remote WIFI Thermostat Temperature Control Module NTC 10K 0.5M Relay Temperature Controller Module
În stoc
De ce îți va plăcea să cumperi de la OnBuy:
- Câștigi Cashback la fiecare achiziție – folosește-l la următoarea comandă
- Livrare gratuită – la milioane de produse de pe site
- Clienții ne iubesc – 135,000 de recenzii cu evaluare “Excelent”
Prețurile articolelor vândute de OnBuy includ TVA.
Opțiuni de plată în rate fără dobândă disponibile
Vezi descrierea completă și detaliile produsului
Livrare: Standard (35,00 RON) | mar 20 - lun 26 oct.
Vândut de: GSbuy
Returnări: 30 zile
Protecție la plată pentru 180 de zile
Te-ar putea interesa și
Rezumat
- 1. Function description of automatic mode: 1) First select heating mode/cooling mode. 2) Set the temperature and hysteresis difference, if you need to delay start, set the time of delay start. 3) If you need to set high and low temperature alarms, set the high and low temperature alarm thresholds yourself
- 2. Description of heating mode: When the detected temperature (current temperature) less than equal set temperature - hysteresis temperature, the relay is turned on, and the heating equipment starts to work. When the detected temperature (current temperature) greater than equal the set temperature, the relay is disconnected and the heating device stops working
- 3. Description of cooling mode: When the detected temperature (current temperature) greater than equal set temperature + hysteresis temperature, the relay is turned on, and the refrigeration equipment starts to work. When the detected temperature (current temperature) less than equal the set temperature, the relay is disconnected and the refrigeration equipment stops working
- 4. Description of delayed start function: After a heating/cooling process is over, how long to delay (unit: seconds) to allow the next heating/cooling. Temperature correction function: If the system works for a long time, there may be deviations, which can be corrected by this function, the current temperature = measured temperature + calibration value
- 5. Emergency braking function (emergency stop function): After the emergency stop is turned on, the relay will be disconnected no matter what state it is in; after the emergency stop is turned off, the relay returns to the normal state. In the automatic mode, when the parameters are set, the product can be disconnected from the network and run offline, and the parameters will not be lost when the power is turned off.
Descriere XY-WFTX Remote WIFI Thermostat Temperature Control Module NTC 10K 0.5M Relay Temperature Controller Module
1. Function description of automatic mode: 1) First select heating mode/cooling mode. 2) Set the temperature and hysteresis difference, if you need to delay start, set the of delay start. 3) If you need to set high and low temperature alarms, set the high and low temperature alarm thresholds yourself
2. Description of heating mode: When the detected temperature (current temperature) less than equal set temperature - hysteresis temperature, the relay is turned , and the heating equipment starts to work. When the detected temperature (current temperature) greater than equal the set temperature, the relay is disconnected and the heating device stops working
3. Description of cooling mode: When the detected temperature (current temperature) greater than equal set temperature + hysteresis temperature, the relay is turned , and the refrigeration equipment starts to work. When the detected temperature (current temperature) less than equal the set temperature, the relay is disconnected and the refrigeration equipment stops working
4. Description of delayed start function: After a heating/cooling process is over, how long to delay (unit: seconds) to allow the next heating/cooling. Temperature correction function: If the system works for a long , there may be deviations, which can be corrected by this function, the current temperature = measured temperature + calibration value
5. Emergency braking function (emergency stop function): After the emergency stop is turned , the relay will be disconnected no matter what state it is in; after the emergency stop is turned off, the relay returns to the normal state. In the automatic mode, when the parameters are set, the product can be disconnected from the network and run offline, and the parameters will not be lost when the power is turned off.
High and low temperature alarm function
Detalii
| OPC | PS5XHVM |
|---|---|
| Coduri | 6032785980011 (EAN) |
| Informații despre produs și siguranță |
Date despre produs
| Height | 2cm |
|---|---|
| Width | 5cm |
| Length | 7cm |
| Weight | 0.034kg |
| Colour | Black |
| Material | plastic |
Compară vânzătorii pentru XY-WFTX Remote WIFI Thermostat Temperature Control Module NTC 10K 0.5M Relay Temperature Controller Module
- Nou de la 123,31 RON
| Vânzător | Note | Garanție | Retururi | Preț | Livrare | Total | Cantitate |
|---|---|---|---|---|---|---|---|
|
Expediat din:
|
(192 recenzii) | - |
30 zile
Retur gratuit Nu
|
88,31 RON
|
+35,00 RON Delivery
Livrare estimată:
20-26 oct.
|
123,31 RON
|
Câștigați în timp ce cumpărați cu Cashback instant la orice produs.
Fără condiții ascunse, fără costuri
- Plătit în contul dumneavoastră OnBuy
- Folosiți-i pentru următoarea achiziție
- Economisiți-l sau retrageți-l
Deveniți un Cashback VIP
O singură achiziție deblochează oferte și rate mai avantajoase





