PH Meter Calibration Solution ORP Tester Calibration Solution Buffer Solutions,ORP 222mV
Skladem
Proč si zamilujete nakupování na OnBuy:
- Získejte Cashback při každém nákupu – využijte jej okamžitě při další objednávce
- Doprava zdarma – u milionů položek na celém webu
- Zákazníci nás mají rádi – 138,000 recenzí s hodnocením “Vynikající”
Ceny zboží prodávaného na OnBuy jsou zobrazeny včetně DPH.
Možnosti platby bez úroků k dispozici
Zobrazit kompletní popis a podrobnosti o produktu
Doručení: Standardní (Zdarma) | úte 24 - sob 28 lis
Prodává: JJBRDZ
Vrácení zboží: 30 dní
180denní ochrana platby
Mohlo by se vám také líbit
Shrnutí
- How to Calibrate the ORP Meter:1.Press ON/OFF button to turn on the meter, take off the protective cap and rinse off the probe with pure water and dry it.
- 2. Press the "MODE/CAL" button to set the ORP mode; the word "mV" will be displayed at the top right of the screen. Put the probe into 222mV calibration solution and shake it gently.
- 3. Wait until the reading is stable, then long press"MODE/CAL" for 5 seconds and release; CAL is displayed on the screen, then a value will flash 3 times on the screen, when the value starts to fiash, press "MODE/CAL" button ( lf the flashing value is higher than 222mV ) or "HOLD/TEMP" button ( lf the flashing value is lower than 222mV ).
- 4. After adjusting the displaying value to 222mV then release the button, waiting the reading stop flashing,the calibration is finished, rinse off the probe with water.
- Calibration Solution
PH Meter Calibration Solution ORP Tester Calibration Solution Buffer Solutions,ORP 222mV Popis
How to Calibrate the ORP Meter:1.Press /OFF button to turn the meter, take off the protective cap and rinse off the probe with pure water and dry it.
2. Press the "MODE/CAL" button to set the ORP mode; the word "mV" will be displayed at the top right of the screen. Put the probe into 222mV calibration solution and shake it gently.
3. Wait until the reading is stable, then long press"MODE/CAL" Compatible?with 5 seconds and release; CAL is displayed the screen, then a value will flash 3 times the screen, when the value starts to fiash, press "MODE/CAL" button ( lf the flashing value is higher than 222mV ) or "HOLD/TEMP" button ( lf the flashing value is lower than 222mV ).
4. After adjusting the displaying value to 222mV then release the button, waiting the reading stop flashing,the calibration is finished, rinse off the probe with water.
Storage:
Buffer solutions should be stored in a dark, cool place (not in the refrigerator and at temperatures no higher than 25C) away from direct sunlight to prevent photochemical degradation. In addition, buffer calibration solutions should be protected from carbon dioxide from the air and stored in tightly closed containers.
Colour:As Shown
Material:plastic
type:ORP 222mV
Package Contents:
1 set x pH Meter
Podrobnosti
| OPC | PYTT7H8 |
|---|---|
| Značka | Torribaly |
| Kódy | 4711602661211 (EAN) |
| Informace o produktu a bezpečnosti |
Produktová data
| Height | 5cm |
|---|---|
| Width | 5cm |
| Length | 7cm |
| Weight | 0.07kg |
| Colour | As Shown |
| Size | ORP 222mV |
| Material | plastic |
Porovnejte prodejce pro PH Meter Calibration Solution ORP Tester Calibration Solution Buffer Solutions,ORP 222mV
- Nové od 620,84 Kč
| Prodejce | Hodnocení | Záruka | Vrácení zboží | Cena | Doručení | Celkem | Množství |
|---|---|---|---|---|---|---|---|
|
Odesláno z:
|
(525 recenzí) | - |
30 dní
Vrácení zboží zdarma Ne
|
620,84 Kč
|
+Free Delivery
Odhadované doručení:
24-28 lis
|
620,84 Kč
|
Získávejte odměny při nákupu s okamžitým Cashback na vše.
Žádný háček, žádné náklady
- Připsáno na váš účet OnBuy
- Využijte je při dalším nákupu
- Ušetřete nebo si je vyberte
Staňte se Cashback VIP
Už po 1 nákupu získáte lepší nabídky a ceny