2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
På lager
Derfor vil du elske at handle hos OnBuy:
- Tjen Cashback på hvert køb – brug det med det samme på din næste ordre
- Gratis levering – på millioner af varer på siden
- Kunder elsker os – 132,000 anmeldelser med vurderingen “Fremragende”
Priserne for varer, der sælges af OnBuy, inkluderer moms.
Rentefrie betalingsmuligheder
Se fuld produktbeskrivelse og detaljer
Levering: Standard (30,00 kr.) | man. 24. - ons. 26. aug.
Solgt af: YPDblue
Returnering: 30 dage
180 dages betalingsbeskyttelse
Du kan også lide
Oversigt
- Single-control UP pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B(blue)-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common line.D(green) and E(yellow)are connected with C (black).
- Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common line.A and B-disconnected
- Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
- Joint control UP and DOWN pool installation instructions :A-Upper water level control point in UP pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
- C-Should be placed in bottom of UP and DOWN pools as the common line.D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay Beskrivelse
Single-control pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B()-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common .D(green) and E(yellow)are connected with C (black).
Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common .A and B-disconnected
Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
Joint control and DOWN pool installation instructions :A-Upper water level control point in pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
C-Should be placed in bottom of and DOWN pools as the common .D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
Type:DF-96D Updated version
Working
Detaljer
| OPC | PTRJ78G |
|---|---|
| Koder | 4713075496413 (EAN) |
| Produkt- og sikkerhedsoplysninger |
Produktdata
| Height | 12cm |
|---|---|
| Width | 9cm |
| Length | 11cm |
| Weight | 0.443kg |
| Colour | creamy-white |
| Material | plastic |
Sammenlign sælgere for 2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
- Ny fra 300,60 kr.
| Sælger | Bedømmelser | Garanti | Returneringer | Pris | Levering | I alt | Antal |
|---|---|---|---|---|---|---|---|
|
Afsendt fra:
|
(282 anmeldelser) | - |
30 dage
Gratis retur Nej
|
270,60 kr.
|
+30,00 kr. Delivery
Forventet levering:
24-26 aug.
|
300,60 kr.
|
Tjen penge, mens du handler med øjeblikkelig Cashback på alt.
Ingen hage, ingen omkostninger
- Indbetalt til din OnBuy-konto
- Brug dem på dit næste køb
- Gem det eller hæv det
Bliv Cashback VIP
Bare 1 køb giver adgang til bedre tilbud og priser