2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
În stoc
De ce îți va plăcea să cumperi de la OnBuy:
- Câștigi Cashback la fiecare achiziție – folosește-l la următoarea comandă
- Livrare gratuită – la milioane de produse de pe site
- Clienții ne iubesc – 132,000 de recenzii cu evaluare “Excelent”
Prețurile articolelor vândute de OnBuy includ TVA.
Opțiuni de plată în rate fără dobândă disponibile
Vezi descrierea completă și detaliile produsului
Livrare: Standard (80,00 RON) | sâm 22 - mar 25 aug.
Vândut de: YPDblue
Returnări: 30 zile
Protecție la plată pentru 180 de zile
Rezumat
- Single-control UP pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B(blue)-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common line.D(green) and E(yellow)are connected with C (black).
- Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common line.A and B-disconnected
- Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
- Joint control UP and DOWN pool installation instructions :A-Upper water level control point in UP pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
- C-Should be placed in bottom of UP and DOWN pools as the common line.D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
Descriere 2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
Single-control pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B()-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common .D(green) and E(yellow)are connected with C (black).
Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common .A and B-disconnected
Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
Joint control and DOWN pool installation instructions :A-Upper water level control point in pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
C-Should be placed in bottom of and DOWN pools as the common .D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
Type:DF-96D Updated version
Working
Detalii
| OPC | PTRJ78G |
|---|---|
| Coduri | 4713075496413 (EAN) |
| Informații despre produs și siguranță |
Date despre produs
| Height | 12cm |
|---|---|
| Width | 9cm |
| Length | 11cm |
| Weight | 0.443kg |
| Colour | creamy-white |
| Material | plastic |
Compară vânzătorii pentru 2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
- Nou de la 204,86 RON
| Vânzător | Note | Garanție | Retururi | Preț | Livrare | Total | Cantitate |
|---|---|---|---|---|---|---|---|
|
Expediat din:
|
(282 recenzii) | - |
30 zile
Retur gratuit Nu
|
124,86 RON
|
+80,00 RON Delivery
Livrare estimată:
22-25 aug.
|
204,86 RON
|
Câștigați în timp ce cumpărați cu Cashback instant la orice produs.
Fără condiții ascunse, fără costuri
- Plătit în contul dumneavoastră OnBuy
- Folosiți-i pentru următoarea achiziție
- Economisiți-l sau retrageți-l
Deveniți un Cashback VIP
O singură achiziție deblochează oferte și rate mai avantajoase