2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
In stock
Smart shoppers OnBuy it!
- Earn Cashback on every purchase – spend it instantly on your next order
- Free delivery – on millions of items across the site
- Customers love us – 132,000 Trustpilot reviews and an 'Excellent' rating
All prices include VAT.
Interest-free payment options available
See full product description & details
Delivery: Standard (€4.00) | Tue 1st - Mon 7th Sep
Sold by: is fearr
Returns: 30 days
180-day payment protection
You might also like
Summary
- Single-control UP pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B(blue)-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common line.D(green) and E(yellow)are connected with C (black).
- Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common line.A and B-disconnected
- Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
- Joint control UP and DOWN pool installation instructions :A-Upper water level control point in UP pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
- C-Should be placed in bottom of UP and DOWN pools as the common line.D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay Description
Single-control pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B()-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common .D(green) and E(yellow)are connected with C (black).
Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common .A and B-disconnected
Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
Joint control and DOWN pool installation instructions :A-Upper water level control point in pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
C-Should be placed in bottom of and DOWN pools as the common .D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
Type:DF-96D Updated version
Working
Details
| OPC | PTRJ78G |
|---|---|
| Codes | 4713075496413 (EAN) |
| Product and Safety Information |
Product Data
| Height | 12cm |
|---|---|
| Width | 9cm |
| Length | 11cm |
| Weight | 0.443kg |
| Colour | creamy-white |
| Material | plastic |
Compare Sellers for 2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
- New from €40.09
| Seller | Ratings | Warranty | Returns | Price | Delivery | Total | Quantity |
|---|---|---|---|---|---|---|---|
|
Dispatched from:
|
(282 reviews) | - |
30 Days
Free Returns No
|
€36.09
|
+€4.00 Delivery
Est. Delivery:
1st-7th Sep
|
€40.09
|
Earn as you shop with instant Cashback on everything.
No catch, no cost
- Paid into your OnBuy account
- Spend it on your next purchase
- Save it or withdraw it
Become a Cashback VIP
Just 1 purchase unlocks bigger deals & rates


