2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
Skladem
Proč si zamilujete nakupování na OnBuy:
- Získejte Cashback při každém nákupu – využijte jej okamžitě při další objednávce
- Doprava zdarma – u milionů položek na celém webu
- Zákazníci nás mají rádi – 132,000 recenzí s hodnocením “Vynikající”
Ceny zboží prodávaného na OnBuy jsou zobrazeny včetně DPH.
Možnosti platby bez úroků k dispozici
Zobrazit kompletní popis a podrobnosti o produktu
Doručení: Standardní (2 145,00 Kč) | sob 5 - čtv 24 zář
Vrácení zboží: 30 dní
180denní ochrana platby
Mohlo by se vám také líbit
Shrnutí
- Single-control UP pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B(blue)-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common line.D(green) and E(yellow)are connected with C (black).
- Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common line.A and B-disconnected
- Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
- Joint control UP and DOWN pool installation instructions :A-Upper water level control point in UP pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
- C-Should be placed in bottom of UP and DOWN pools as the common line.D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay Popis
Single-control pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B()-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common .D(green) and E(yellow)are connected with C (black).
Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common .A and B-disconnected
Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
Joint control and DOWN pool installation instructions :A-Upper water level control point in pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
C-Should be placed in bottom of and DOWN pools as the common .D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
Type:DF-96D Updated version
Working
Podrobnosti
| OPC | PTRH9FQ |
|---|---|
| Kódy | 4712044178640 (EAN) |
| Informace o produktu a bezpečnosti |
Produktová data
| Height | 12cm |
|---|---|
| Width | 9cm |
| Length | 11cm |
| Weight | 0.443kg |
| Colour | creamy-white |
| Material | plastic |
Porovnejte prodejce pro 2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
- Nové od 2 831,49 Kč
| Prodejce | Hodnocení | Záruka | Vrácení zboží | Cena | Doručení | Celkem | Množství |
|---|---|---|---|---|---|---|---|
|
Odesláno z:
|
(121 recenzí) | - |
30 dní
Vrácení zboží zdarma Ne
|
686,49 Kč
|
+2 145,00 Kč Delivery
Odhadované doručení:
5-24 zář
|
2 831,49 Kč
|
Získávejte odměny při nákupu s okamžitým Cashback na vše.
Žádný háček, žádné náklady
- Připsáno na váš účet OnBuy
- Využijte je při dalším nákupu
- Ušetřete nebo si je vyberte
Staňte se Cashback VIP
Už po 1 nákupu získáte lepší nabídky a ceny