2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
På lager
Derfor vil du elske å handle hos OnBuy:
- Tjen Cashback på hvert kjøp – bruk det umiddelbart på din neste bestilling
- Gratis levering – på millioner av varer på hele nettstedet
- Kunder elsker oss – 132,000 anmeldelser med vurderingen “Utmerket”
Prisene for varer solgt av OnBuy inkluderer mva.
Rente- og gebyrfri delbetaling tilgjengelig
Se full produktbeskrivelse og detaljer
Levering: Standard (Gratis) | tir 1. - man 7. sep
Returer: 30 dager
180 dagers betalingsbeskyttelse
Du vil kanskje også like
Sammendrag
- Single-control UP pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B(blue)-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common line.D(green) and E(yellow)are connected with C (black).
- Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common line.A and B-disconnected
- Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
- Joint control UP and DOWN pool installation instructions :A-Upper water level control point in UP pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
- C-Should be placed in bottom of UP and DOWN pools as the common line.D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay Beskrivelse
Single-control pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B()-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common .D(green) and E(yellow)are connected with C (black).
Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common .A and B-disconnected
Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
Joint control and DOWN pool installation instructions :A-Upper water level control point in pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
C-Should be placed in bottom of and DOWN pools as the common .D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
Type:DF-96D Updated version
Working
Detaljer
| OPC | PTRH9FQ |
|---|---|
| Koder | 4712044178640 (EAN) |
| Produkt- og sikkerhetsinformasjon |
Produktdata
| Height | 12cm |
|---|---|
| Width | 9cm |
| Length | 11cm |
| Weight | 0.443kg |
| Colour | creamy-white |
| Material | plastic |
Sammenlign selgere for 2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
- Ny fra 332,20 kr
| Selger | Vurderinger | Garanti | Returer | Pris | Levering | Totalt | Antall |
|---|---|---|---|---|---|---|---|
|
Sendt fra:
|
(121 anmeldelser) | - |
30 dager
Gratis retur Nei
|
332,20 kr
|
+Free Delivery
Estimert levering:
1-7 sep
|
332,20 kr
|
Tjen mens du handler med umiddelbar Cashback på alt.
Ingen binding, ingen kostnad
- Utbetalt til OnBuy-kontoen din
- Bruk det på neste kjøpet ditt
- Spar den eller ta den ut
Bli en Cashback VIP
Bare 1 kjøp gir deg større rabatter og bedre priser