2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
Varastossa
Miksi tulet rakastamaan ostoksia OnBuyssa:
- Ansaitse Cashback jokaisesta ostoksesta – käytä se heti seuraavaan tilaukseesi
- Ilmainen toimitus – miljooniin tuotteisiin sivustolla
- Asiakkaat rakastavat meitä – 132,000 arvostelua arvosanalla “Erinomainen”
OnBuyn myymien tuotteiden hinnat sisältävät ALV:n.
Korottomat maksuvaihtoehdot saatavilla
Katso koko tuotekuvaus ja tiedot
Toimitus: Vakio (4,20 €) | ti 1. - ma 7. syys
Palautukset: 30 päivää
180 päivän maksuturva
Saattaisit pitää myös näistä
Yhteenveto
- Single-control UP pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B(blue)-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common line.D(green) and E(yellow)are connected with C (black).
- Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common line.A and B-disconnected
- Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
- Joint control UP and DOWN pool installation instructions :A-Upper water level control point in UP pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
- C-Should be placed in bottom of UP and DOWN pools as the common line.D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay Kuvaus
Single-control pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B()-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common .D(green) and E(yellow)are connected with C (black).
Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common .A and B-disconnected
Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
Joint control and DOWN pool installation instructions :A-Upper water level control point in pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
C-Should be placed in bottom of and DOWN pools as the common .D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
Type:DF-96D Updated version
Working
Tiedot
| OPC | PTRH9FQ |
|---|---|
| Koodit | 4712044178640 (EAN) |
| Tuote- ja turvallisuustiedot |
Tuotetiedot
| Height | 12cm |
|---|---|
| Width | 9cm |
| Length | 11cm |
| Weight | 0.443kg |
| Colour | creamy-white |
| Material | plastic |
Vertaile myyjiä tuotteelle 2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
- Uusi alkaen 33,32 €
| Myyjä | Arviot | Takuu | Palautukset | Hinta | Toimitus | Yhteensä | Määrä |
|---|---|---|---|---|---|---|---|
|
Lähetetty varastolta:
|
(121 arvostelua) | - |
30 päivää
Ilmaiset palautukset Ei
|
29,12 €
|
+4,20 € Delivery
Arvioitu toimitus:
1-7 syys
|
33,32 €
|
Ansaitse ostamalla – saat välittömän Cashback-hyvityksen kaikesta.
Ei koukkuja, ei kuluja
- Maksetaan OnBuy-tilillesi
- Käytä se seuraavaan ostokseesi
- Säästä se tai nosta se
Ryhdy Cashback VIP -jäseneksi
Vain yksi ostos avaa suuremmat tarjoukset ja paremmat alennukset