2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
Na sklade
Prečo si zamilujete nakupovanie na OnBuy:
- Získajte cashback pri každom nákupe – použite ho okamžite na ďalšiu objednávku
- Doprava zadarmo – na milióny produktov na celej stránke
- Zákazníci nás milujú – 132,000 hodnotení s “Vynikajúcim” hodnotením
Ceny produktov predávaných spoločnosťou OnBuy sú uvedené s DPH.
Zobraziť celý popis a podrobnosti o produkte
Doručenie: Štandard (4,20 €) | str 2 - uto 8 sep
Vrátenie tovaru: 30 dní
180-dňová ochrana platieb
Mohlo by sa vám tiež páčiť
Zhrnutie
- Single-control UP pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B(blue)-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common line.D(green) and E(yellow)are connected with C (black).
- Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common line.A and B-disconnected
- Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
- Joint control UP and DOWN pool installation instructions :A-Upper water level control point in UP pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
- C-Should be placed in bottom of UP and DOWN pools as the common line.D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay Popis
Single-control pool (water storage) :A(red)-Upper water level control point. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B()-Lower water level control point. When water level gets off B point,the probe out of reach water and controller can start the pump by auto.C(black)-Should be placed in bottom of pool as the common .D(green) and E(yellow)are connected with C (black).
Single-control DOWN pool(drain water):E-Upper water level control point. When water level gets to E point,the probe Contact water and controller can start the pump by auto.D-Lower water level control point. As liquid level gets off D point,the probe out of reach water and controller can stop the pump by auto.C-Should be placed in bottom of pool as the common .A and B-disconnected
Lack of water protection:C and D-Lower water level control points. When water level gets off this point,C or D probe out of reach water and controller can stop the pump by auto.E and C-short-connected;A and B-disconnected
Joint control and DOWN pool installation instructions :A-Upper water level control point in pool. When water level gets to A point,the probe Contact water and controller can stop the pump by auto.B-Lower water level control point in pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.
C-Should be placed in bottom of and DOWN pools as the common .D-Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.E-Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected
Type:DF-96D Updated version
Working
Podrobnosti
| OPC | PTRH9FQ |
|---|---|
| Kódy | 4712044178640 (EAN) |
| Informácie o produkte a bezpečnosti |
Údaje o produkte
| Height | 12cm |
|---|---|
| Width | 9cm |
| Length | 11cm |
| Weight | 0.443kg |
| Colour | creamy-white |
| Material | plastic |
Porovnajte predajcov pre 2X DF-96D Automatic Water Level Controller Pump Cistern Auto Liquid 220V Relay
- Nové od 28,49 €
| Predajca | Recenzie | Záruka | Vrátenie tovaru | Cena | Doručenie | Celkom | Množstvo |
|---|---|---|---|---|---|---|---|
|
Odoslané z:
|
(121 recenzií) | - |
30 dní
Bezplatné vrátenie tovaru Nie
|
24,29 €
|
+4,20 € Delivery
Odhadované doručenie:
2-8 sep
|
28,49 €
|
Zarábajte pri nakupovaní s okamžitým Cashback na všetko.
Žiadny háčik, žiadne náklady
- Pripísané na váš OnBuy účet
- Použite ho na váš ďalší nákup
- Ušetrite alebo si vyberajte
Staňte sa Cashback VIP
Už 1 nákup odomkne lepšie ponuky a zľavy