Sorry, this item is temporarily out of stock.
4X P-55SI High Precision VU Meter DB Meter Amplifier Audio Panel Level Meter with Backlight
Similar Products we think you'll like
Would you like us to let you know when it's back?
Summary
- Electrical performance:Standard test conditions: temperature 20 Celsius, humidity 70%, if there is no difference in the test results, the test can also be performed at normal temperature and humidity.Current sensitivity:Pointer from zero scale to maximum scale (full scale position) Sensitivity 250 uA ± 10 %
- Internal impedance: 650 ohm ± 10 %.Insulation resistance: 500V DC plus 50M ohm or more for the outer box of the meter and the electrical circuit. The insulation resistance of the meter housing and the electrical circuit is tested by 500V DC voltage.Zero position: the standard position of the meter is used, and the point where the front of the pointer and the center of the zero scale are unified is the reference pointer and the zero scale overlap. The tolerance is ± 1mm.
- Balance: The allowable error range of the meter when the standard position is tilted 90 degrees forward and backward is ± 1mm.The pointer sticks: When the full-scale current triples the overcurrent in an instant and slowly reduces to the current sensitivity reading of 1/2, the pointer will return to the scale of 1/3 of the scale.Friction: When the current is added to the meter and slowly increased or decreased to a certain value, the error range of the indicated point is ± 1mm.
- Braking: instantly add 2/3 of the current value of the scale plate, within one second from the start to the position indicated by the pointer
- Led vu meter module
4X P-55SI High Precision VU Meter DB Meter Amplifier Audio Panel Level Meter with Backlight Description
Electrical performance:Standard test conditions: temperature 20 Celsius, humidity 70%, if there is no difference in the test results, the test can also be performed at normal temperature and humidity.Current sensitivity:Pointer from zero scale to maximum scale (full scale position) Sensitivity 250 uA 10 %
Internal impedance: 650 ohm 10 %.Insulation resistance: 500V 50M ohm or more for the outer box of the meter and the electrical circuit. The insulation resistance of the meter housing and the electrical circuit is tested by 500V voltage.Zero position: the standard position of the meter is used, and the point where the front of the pointer and the center of the zero scale are unified is the reference pointer and the zero scale overlap. The tolerance is 1mm.
Balance: The allowable error range of the meter when the standard position is tilted 90 degrees forward and backward is 1mm.The pointer sticks: When the full-scale current triples the overcurrent in an instant and slowly reduces to the current sensitivity reading of 1/2, the pointer will return to the scale of 1/3 of the scale.Friction: When the current is added to the meter and slowly increased or decreased to a certain value, the error range of the indicated point is 1mm.
Braking: instantly add 2/3 of the current value of the scale plate, within one second from the start to the position indicated by the pointer
Special Test:
Overload test: input ten times the full-scale current every five seconds, the action is repeated nine times. Each is 0.5 seconds, after this test remains normal
Vibration test: After the meter is packaged, perform 1,000 vibrations and down 4mm per minute the vibration plate for 10 minutes in each direction. After this test, 7-14 items remain normal.
Impact test: After the packaging of the electric meter, it is dropped fro
Details
| OPC | PV96K97 |
|---|---|
| Codes | 4714250107575 (EAN) |
Product Data
| Height | 16cm |
|---|---|
| Width | 7cm |
| Length | 8cm |
| Weight | 0.196kg |
| Colour | Black & Yellow |
| Material | Zinc cupronickel |