Hart475 Handheld Hart Field Communicator With English Menu For Pressure Temperature Transmitter Calibration

New

Hurry only 1 left

Smart shoppers OnBuy it!

  • Earn Cashback on every purchase – spend it instantly on your next order
  • Free delivery – on millions of items across the site
  • Customers love us – 131,000 Trustpilot reviews and an 'Excellent' rating

See full product description & details

£430.00
FREE Delivery
1% Earn £4.30 instantly Learn More
Add to Basket

Interest-free payment options available

See full product description & details

Delivery: Standard (Free) | Sat 15th - Tue 18th Aug

Sold by: RoyalCartz

Returns: 30 days

180-day payment protection

Add to Basket

You might also like

Description & Details

Hart475 Handheld Hart Field Communicator With English Menu For Pressure Temperature Transmitter Calibration Description

Note: The appearance of the charger is changed to the picture above Descriptions: âºThe HART475 Communicator is an upgraded version of the HART375 Communicator, which is used with the HART communication protocol instrument to set, change and display it, which monitors input / output values ââand self-diagnostic results. Set the constant current output and zero. When the system is activated or maintained operation, as long as the HART Communicator connected to 4 ~ 20mA communication signal line, you can use. ⺠This communication device is suitable for HART protocol intelligent transmitter communication operation, and HART275, HART375, HART475 compatible, with excellent compatibility, communication 1151,3051, EJA, ABB and other HART protocol imported instruments, fully compatible with the domestic A variety of intelligent pressure (temperature) transmitter, but also with the electromagnetic flowmeter, V cone flowmeter, target flowmeter, bow wave flowmeter support HART protocol flow meter communication operation. Features: â During the on-line monitoring and communication communication, the modulation signal does not interrupt the 4 ~ 20mA DC signal â HOM communicator with HART communication protocol HART Communicator can be used with all instruments using HART communication protocol â Easy to operate large screen (4 lines, each line of 18 characters), the use of Chinese display, the user saw a clear, set and change convenience â Information self-diagnosis / protection function â Full-function communication: communication support HART protocol flow meter, temperature meter, transmitter â large screen display: display interface larger and clearer, the use of imported LCD screen â HART intelligent equipment can be produced for testing, diagnosis and inspection â Configuration, calibration, diagnostics, maintenance, monitoring, etc. for HART intelligent devices in the field â Obtain the manufacturer information of the field HART meter â Understand the working status and fault information of the HART meter â Read the output current and process variables of the meter â Obtain the parameters and output values ââof the sensor â Set, change and display various parameters, HART communication â Constant current output â Zero Additional features: â Format protection requires a password to be formatted â Battery Alarm The alarm information displayed on the LCD indicates that the battery voltage is low Specifications: Load resistance: 250 ~ 600Î Load capacitance: 0.22uF The following load inductance: 3.3mH the following: (1) () () () () () () () () () () And the power line spacing: 15cm or more (to avoid parallel alignment) Display: 128 * 64 dot matrix LCD Display control: touch switch (4 arrow keys, 16 function keys, a power switch) LCD contrast adjustment normal working conditions Ambient temperature: -15 ~ 55 â Storage conditions: Ambient temperature: 0 ~ 50 â Weight:~1.5kg Battery: 3 x built-in rechargeable nickel-metal hydride battery Package includes: 1 x Charger 1 x Cable 1 x Communicator 1 x Bag 1 x Use Manual Detail pictures:

Details

OPC PCPHDTS
Codes 3796737023609 (EAN)
Rank #222 Electrical & Test Equipment

Product Images

Hart475 Handheld Hart Field Communicator With English Menu For Pressure Temperature Transmitter Calibration 1
Hart475 Handheld Hart Field Communicator With English Menu For Pressure Temperature Transmitter Calibration 2
Hart475 Handheld Hart Field Communicator With English Menu For Pressure Temperature Transmitter Calibration

Compare Sellers for Hart475 Handheld Hart Field Communicator With English Menu For Pressure Temperature Transmitter Calibration

  • New from £430.00
Seller Ratings Warranty Returns Price Delivery Total Quantity
(138 reviews)
-
30 Days
Free Returns No
£430.00
+Free Delivery
Est. Delivery: 15th-18th Aug
£430.00
Add To Basket

Earn as you shop with instant Cashback on everything.

No catch, no cost

  • Paid into your OnBuy account
  • Spend it on your next purchase
  • Save it or withdraw it

Become a Cashback VIP

Just 1 purchase unlocks bigger deals & rates

Wait! You've left
something behind

You'll only get instant Cashback at OnBuy! Enter your email below and we'll send you a copy of your basket to save you time later.

By entering your email address, you'll automatically be added to our database, where you can enjoy personalised Cashback offers and early access to our best deals. You can opt out of our emails at any time and we'll never share your details with anyone. Check our Privacy Policy and T&Cs to find out more.

Before you go...
Remember, you'll only get instant Cashback on everything at OnBuy!

Want access to personalised offers and the highest Cashback rates? Sign up to our emails below.

You can opt out of our emails at any time and we'll never share your details with anyone. Check our Privacy Policy and T&Cs to find out more.

This page has expired.

Please refresh the page to continue shopping.

Refresh and continue